Product Description
The TESTOMAT® EVO TH determines the water hardness automatically by means of titration. For this purpose, 4 indicators for different measuring ranges from 0.89 448 ppm CaCO3 are available. As a special version, the TESTOMAT® EVO TH CAL is equipped with a calibration function. Technologically, the TESTOMAT ® EVO TH was developed on basis of the TESTOMAT® ECO and, additionally to the approved functions, it is equipped with further new functionalities such as an integrated SD-card for recording the measured values and fault messages.
Furthermore, the SD-card enables an easy implementation of firmware updates as well as the transmission of saved application profiles. A wireless data transmission via WLAN SD-card is optionally available for the TESTOMAT® EVO TH.
Applications
Water treatment plants
Industrial boilers
Monitoring of process water
Drinking water treatment plants
Simple parameterization via SD-card
Optical water detection when filling the measuring chamber
Import and export of settings (basic programming) with selectable file name, logging of measuring data and messages/alarms via integrated SD-card or optional SDHC-card (2 GByte)
Firmware updates via SD-card
LCD graphic display
Multi-lingual menu navigation with simple switching (internal programming is retained)
Integrated self-test with continuous monitoring
External clearing / acknowledgement input
Freely programmable password
Automatic bleeding of the indicator line
Doors individually changeable
Range monitoring (deviation of lower limit value / exceedance of upper limit value)
Free programming of permitted number of water shortages (for systems with temporarily low water pressure)
Accessories
WLAN SD-card, Order No. 100491
Types of indicator in units °dH / °f / ppm CaCO3 / mmol/l are available in 100 ml or 500 ml bottles.
Technical Specifications
Supply voltage: 230 VAC, 50-60 Hz Order No. 100703
Wide range power adapter: 100-240 VAC, 100-353 VDC Order No. 100704
Power consumption: max. 30 VA
Protection class: 1
Protection type: IP 44
Ambient temperature: 1040 °C
Water temperature: 1040 °C
Dimensions (W x H x D): 380 x 480 x 280 mm
Water inlet: opaque hose with 6 mm outer diameter / 4 mm inner diameter
Water outlet: hose with 12 mm inner diameter
Weight: approx. 9.0 kg
Operating pressure: 1 to 8 bar/1x105 to 8x105 Pa or
0.3* to 1 bar/0.3x105 to 8x105 Pa (after removing the regulator core)
Languages: German, English, French, Dutch, Czech, Spanish, Turkish, Chinese
(further languages upon request)
Measuring range: 0.89 448 ppm CaCO3 (depending on type of indicator)