{"product_id":"siata-conversion-fitting-kit","title":"Siata Conversion Fitting kit Socket Union 2\" external \u003e 1 1\/4\" Internal (nylon) 2 required","description":"\u003cdiv dir=\"ltr\" aria-busy=\"false\" aria-live=\"off\" id=\"model-response-message-contentr_ef2f5784c57cfaed\" class=\"markdown markdown-main-panel stronger enable-updated-hr-color\"\u003e\n\u003ch2 data-path-to-node=\"0\"\u003eSimplify Your Upgrades: Siata 2\" to 1 1\/4\" Conversion Fitting Kit\u003c\/h2\u003e\n\u003cp data-path-to-node=\"1\"\u003eModernize your water treatment setup with the \u003cb data-index-in-node=\"46\" data-path-to-node=\"1\"\u003eSiata Conversion Fitting Kit\u003c\/b\u003e. Specifically designed to bridge the gap between legacy systems and modern pipework, this kit allows for a seamless transition from \u003cb data-index-in-node=\"207\" data-path-to-node=\"1\"\u003e2\" external socket unions\u003c\/b\u003e to \u003cb data-index-in-node=\"236\" data-path-to-node=\"1\"\u003e1 1\/4\" internal\u003c\/b\u003e connections.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eWhether you are replacing an obsolete valve—like the Siata \u003cb data-index-in-node=\"59\" data-path-to-node=\"2\"\u003eV132A-BFE\/05\u003c\/b\u003e—or reconfiguring your filtration vessel, this durable nylon kit provides a professional-grade solution without the need for extensive pipework modifications.\u003c\/p\u003e\n\u003chr data-path-to-node=\"3\"\u003e\n\u003ch3 data-path-to-node=\"4\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4\"\u003eKey Features \u0026amp; Benefits\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,0,0\"\u003eSeamless Conversion:\u003c\/b\u003e Easily adapts a 2\" external socket union thread down to a 1 1\/4\" (32mm) internal connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,0\"\u003eCorrosion-Proof Material:\u003c\/b\u003e Crafted from high-quality \u003cb data-index-in-node=\"52\" data-path-to-node=\"5,1,0\"\u003ereinforced Nylon\u003c\/b\u003e, offering excellent chemical resistance and durability in wet environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,2,0\"\u003eSystem Longevity:\u003c\/b\u003e Ideal for maintaining or upgrading older Siata installations where original 2\" parts are no longer available.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,3,0\"\u003eMinimal Disruption:\u003c\/b\u003e Engineered to allow existing pipework to remain in place, typically requiring only a minor adjustment (approx. 1 inch) to the vessel position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,4,0\"\u003eFull Installation Set:\u003c\/b\u003e Sold as a required pair (2 fittings) to cover both the inlet and outlet ports of your control valve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6\"\u003eProduct Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"7\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,1,0,0\"\u003eMaterial\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,1,0\"\u003eHigh-Grade Nylon\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,2,0,0\"\u003eExternal Connection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,1,0\"\u003e2\" Socket Union\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,3,0,0\"\u003eInternal Connection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,1,0\"\u003e1 1\/4\" (32mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,4,0,0\"\u003eQuantity Included\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,4,1,0\"\u003e1 Fitting (2 required for complete Kit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,5,0,0\"\u003ePrimary Compatibility\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,5,1,0\"\u003eSiata V132, V230, V250 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,6,0,0\"\u003eCommon Use\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,6,1,0\"\u003eReplacing Obsolete V132A-BFE\/05 Valves\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr data-path-to-node=\"8\"\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9\"\u003eInstallation Note\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThis kit is the industry-standard solution for technicians looking to adapt larger valve ports to standard 1 1\/4\" plumbing. Because these fittings add a small amount of length to the valve assembly, ensure you have approximately \u003cb data-index-in-node=\"229\" data-path-to-node=\"10\"\u003e25mm (1 inch)\u003c\/b\u003e of clearance to move your pressure vessel during installation.\u003c\/p\u003e\n\u003cblockquote data-path-to-node=\"11\"\u003e\n\u003cp data-path-to-node=\"11,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,0\"\u003eImportant:\u003c\/b\u003e Always use a high-quality thread sealant or silicone grease on the union faces to ensure a pressure-tight seal without over-torquing the nylon \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cdiv dir=\"ltr\" aria-busy=\"false\" aria-live=\"polite\" id=\"model-response-message-contentr_522b70ffffa7b672\" class=\"markdown markdown-main-panel stronger enable-updated-hr-color\"\u003e\n\u003cp data-path-to-node=\"0\"\u003eReplacing an obsolete Siata V132 valve with a modern equivalent using the \u003cb data-index-in-node=\"74\" data-path-to-node=\"0\"\u003e2\" to 1 1\/4\" Conversion Fitting Kit\u003c\/b\u003e is a common task for water treatment professionals. Because the new assembly is slightly longer than the original, following these steps ensures a leak-free installation without stressing your pipework.\u003c\/p\u003e\n\u003chr data-path-to-node=\"1\"\u003e\n\u003ch2 data-path-to-node=\"2\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"2\"\u003eTechnical Guide: Replacing a Siata V132 Valve\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3 data-path-to-node=\"3\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3\"\u003ePre-Installation Checklist\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,0,0\"\u003eSpace Requirements:\u003c\/b\u003e Ensure you have approximately \u003cb data-index-in-node=\"50\" data-path-to-node=\"4,0,0\"\u003e25mm (1 inch)\u003c\/b\u003e of lateral movement in your pipework or the ability to slide your pressure vessel slightly to accommodate the added length of the conversion fittings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,1,0\"\u003eTools Needed:\u003c\/b\u003e Strap wrench (to avoid scarring nylon), silicone grease (NSF 61), and a pipe cutter (if adjustments are needed).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,2,0\"\u003eParts:\u003c\/b\u003e 1x New Control Valve, 2x Conversion Fittings (2\" External \u0026gt; 1 1\/4\" Internal), and new O-rings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"5\"\u003e\n\u003ch3 data-path-to-node=\"6\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6\"\u003eStep-by-Step Installation\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4 data-path-to-node=\"7\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7\"\u003e1. System Isolation \u0026amp; Depressurization\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003eTurn off the water supply to the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003eInitiate a manual regeneration cycle to relieve internal pressure, then unplug the power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003eDisconnect the existing union nuts from the old V132 valve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9\"\u003e2. Prepare the Conversion Fittings\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003eInspect the \u003cb data-index-in-node=\"12\" data-path-to-node=\"10,0,0\"\u003eNylon Conversion Fittings\u003c\/b\u003e for any molding flash or debris.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003eApply a thin, even coat of \u003cb data-index-in-node=\"27\" data-path-to-node=\"10,1,0\"\u003eMolykote 111\u003c\/b\u003e or similar silicone grease to the internal and external threads\/O-ring seats.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003ci data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eNote: Do not use PTFE tape on these nylon unions unless specifically directed, as the O-ring provides the primary seal.\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003e3. Fitting the Adapters to the New Valve\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003eThread the \u003cb data-index-in-node=\"11\" data-path-to-node=\"12,0,0\"\u003e2\" external\u003c\/b\u003e side of the conversion fittings into the inlet and outlet ports of your new valve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003eTighten them \u003cb data-index-in-node=\"13\" data-path-to-node=\"12,1,0\"\u003ehand-tight plus a 1\/4 turn\u003c\/b\u003e using a strap wrench. Over-tightening nylon can lead to stress fractures over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13\"\u003e4. Aligning the Vessel\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003eSince the new configuration is slightly longer, you will likely need to shift your pressure vessel (the tank) roughly \u003cb data-index-in-node=\"118\" data-path-to-node=\"14,0,0\"\u003e1 inch\u003c\/b\u003e away from the main plumbing headers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003eIf your pipework is rigid (Copper or PVC), you may need to trim a small section of the pipe to maintain proper alignment and prevent \"side-loading\" the valve ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"15\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15\"\u003e5. Connecting the 1 1\/4\" Unions\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eAlign the existing 1 1\/4\" pipe unions with the internal threads of the conversion kit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eEnsure the seating O-rings are centered.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eTighten the union nuts securely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"17\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"17\"\u003e6. Testing \u0026amp; Startup\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"18\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,0,0\"\u003eSlowly open the inlet bypass valve to 25% to allow the system to pressurize gradually.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,1,0\"\u003eCheck for leaks around the conversion fitting threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,2,0\"\u003eOnce pressurized, fully open the inlet and outlet valves and run a test cycle to ensure the flow rate is consistent.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"19\"\u003e\n\u003ch3 data-path-to-node=\"20\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"20\"\u003eMaintenance Tip\u003c\/b\u003e\u003c\/h3\u003e\n\u003cblockquote data-path-to-node=\"21\"\u003e\n\u003cp data-path-to-node=\"21,0\"\u003eRe-check the tightness of the nylon unions after \u003cb data-index-in-node=\"49\" data-path-to-node=\"21,0\"\u003e24–48 hours\u003c\/b\u003e of operation. Thermal expansion from water temperature fluctuations can occasionally cause the nylon to \"settle,\" requiring a slight manual snugging.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp data-path-to-node=\"22\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siata","offers":[{"title":"Default Title","offer_id":57078541418878,"sku":"10446000109  |  0303290006","price":12.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0648\/3227\/4627\/files\/siata2inchto1quarterinch.jpg?v=1773936896","url":"https:\/\/www.gapswater.co.uk\/products\/siata-conversion-fitting-kit","provider":"GAPS Water Treatment","version":"1.0","type":"link"}