Product Description
Application
Possible on valves WS1 WS1.25 and controllers TC, EI and CI
Only compatible with new 15 V DC Clack adapters (V3186EU-05 and V3186EU-06)
How does it work?
As of the start of a regeneration, the micro switch is opened and the chlorine generator is provided with the voltage. The voltage will be supplied to the generator through the entire regeneration cycle; but will only create amperage when brine is ran across the probes to create the chlorine. So the length in which the generator is powered would be the length of the regeneration cycle; the portion in which it is active would only be the time it seeing brine. Essentially from the time it goes into brine draw until the air check seals in the brine tank. The chlorine generator is providing approximately 2ppm of chlorine.