G-QS-740 Replacement Sterlight QS-740 Quartz Sleeve for SP740-HO

SKU: G-QS-740
Regular price £81.60
Shipping calculated at checkout.

Technical Resources

Questions & Answers loading...

G-QS-740 Replacement Sterilight QS-740 Quartz Sleeve for SP740-HO

Maintain the performance and reliability of your UV water treatment system with the G-QS-740 Replacement Quartz Sleeve, a premium compatible replacement for the Sterilight / Viqua QS-740. Manufactured from high-quality fire-polished fused quartz, this sleeve provides exceptional UV light transmission while protecting the UV lamp from direct contact with water.

Featuring a closed (domed) one-end design, the G-QS-740 is supplied complete with two replacement EPDM O-rings for a secure, leak-free installation. It is compatible with a wide range of Sterilight, Viqua, Evoqua and Pura Water UV disinfection systems.

Over time, mineral deposits such as limescale, iron and manganese can build up on the quartz sleeve, reducing UV transmission and lowering the effectiveness of your UV steriliser. Regular cleaning and scheduled replacement help maintain optimum UV output and ensure reliable protection against bacteria, viruses and other harmful microorganisms.

Features & Benefits

  • Compatible replacement for Sterilight / Viqua QS-740
  • Premium fire-polished fused quartz
  • Closed (domed) one-end design
  • Excellent UV light transmission for maximum disinfection performance
  • Protects the UV lamp from direct water contact
  • Supplied complete with 2 EPDM O-rings
  • Precision manufactured for a secure, leak-free seal
  • Easy to install during routine maintenance
  • Cost-effective alternative to the OEM quartz sleeve

Technical Specifications

  • Product Code: G-QS-740
  • Replaces: Sterilight / Viqua QS-740
  • Length: 872 mm
  • Outside Diameter: 23 mm (22.5 mm nominal)
  • Inside Diameter: 20 mm
  • End Type: Closed (Domed) One End
  • Material: Fire-polished fused quartz
  • Supplied with: 2 × EPDM O-rings

Maintenance Recommendations

For optimum UV system performance:

  • Clean the quartz sleeve every 6–12 months, depending on water quality.
  • Remove mineral deposits using Calcium, Lime & Rust (CLR) remover or white vinegar.
  • Replace the quartz sleeve every 2 years, even if it appears undamaged.
  • Inspect the O-rings during servicing and replace them if worn or damaged.

Compatible UV Lamp

Designed for use with the Sterilight / Viqua S740RL-HO UV lamp.

Compatible UV Systems

Evoqua Water Technologies

  • W2T376902

Pura Water Products

  • 89512
  • UVSS-15
  • UVSS-15M

UV Superstore

  • 89512-UV

Sterilight / R-Can

  • QS-740
  • S740RL-HO
  • SC-740
  • SCM-740
  • SCMV-740
  • SCV-740
  • SP740-HO
  • SPV-15
  • SPV-740

Viqua

  • QS-740
  • S740RL-HO
  • SC-740
  • SCM-740
  • SCMV-740
  • SCV-740
  • SP740-HO
  • SPV-15
  • SPV-740

This compatibility is based on published manufacturer cross-reference information for the QS-740 quartz sleeve.

The G-QS-740 is a premium compatible replacement quartz sleeve offering exceptional optical clarity, durability and long service life. Manufactured to high standards, it provides a cost-effective alternative to the original Sterilight / Viqua QS-740 while maintaining the UV transmission required for effective ultraviolet water disinfection.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Frequently Asked Questions

How often should I replace the quartz sleeve in my UV system?
It is recommended to replace the quartz sleeve every 2 years to maintain maximum UV transmission and consistent disinfection performance, even if the sleeve appears undamaged.
What maintenance is required to keep the quartz sleeve in optimal condition?
Regular cleaning every 6–12 months using minerals deposit removers like CLR or vinegar, and inspecting and replacing the O-rings during servicing, will help keep the quartz sleeve operating effectively.
How often should I replace or clean the quartz sleeve for optimal performance?
It is recommended to clean the quartz sleeve every 6-12 months depending on water quality and replace it every 2 years to maintain maximum UV transmission and disinfection effectiveness.
How often should I replace or clean the quartz sleeve for optimal performance?
It is recommended to clean the quartz sleeve every 6 to 12 months depending on water quality and replace the sleeve approximately every 2 years to maintain maximum UV transmission and disinfection performance.
What maintenance is required to ensure optimal performance of the quartz sleeve?
Regular cleaning every 6-12 months using CLR remover or white vinegar helps remove mineral deposits. It’s also recommended to replace the quartz sleeve every 2 years to maintain maximum UV transmission.
What is the G-QS-740 Replacement Quartz Sleeve used for?
The G-QS-740 Replacement Quartz Sleeve is designed to maintain optimal UV performance in water treatment systems by protecting the UV lamp, especially for systems using the Viqua QS-001 or similar models.
Is the G-QS-740 compatible with other UV water disinfection systems besides Viqua?
Yes, this quartz sleeve is compatible with a wide range of systems, including Sterilight, Evoqua, Pura Water, and Viqua UV disinfection units, ensuring versatile use across various models.
How often should I replace or clean the quartz sleeve for best performance?
It is recommended to clean the quartz sleeve every 6 to 12 months using CLR remover or white vinegar, and to replace it every 2 years to ensure maximum UV transmission and effective disinfection.