Clack WS2 CI Noryl Timed Filter Valve Kit – No DLFC
Technical Resources
Technical Resources
Clack WS2 CI Noryl Timed Filter Valve Kit
The Clack WS2 CI is a heavy-duty 2" top-mount control valve designed for commercial and industrial water filtration applications. This timed filter valve kit is supplied without a DLFC, making it suitable where the drain flow control is to be selected separately to suit the vessel size, media and required backwash rate.
The glass-filled composite valve body provides a robust, corrosion-resistant alternative to metal valves, while the CI electronic controller offers fully programmable regeneration cycles and reliable automatic operation.
Key Features
- 2" commercial/industrial top-mount control valve
- Noryl / glass-filled composite valve body
- Timed filter configuration
- Up to 9 programmable regeneration cycles
- Programmable backwash, rinse and pause/service cycle times
- 24-hour clock with solid-state microprocessor controller
- Reliable DC drive with linearly reciprocating piston
- One-piece expanding seal and spacer stack assembly
- Suitable for filter vessels from 12" to 36" diameter
- Supplied without DLFC
Flow Rates
- Service flow: up to 21.6 m³/hr at 1 bar pressure drop
- Backwash flow: up to 19.3 m³/hr at 1.7 bar pressure drop
Technical Specification
- Inlet / outlet: 2" connections
- Tank mounting thread: 4" - 8 UN
- Riser / distributor tube: 50 mm OD
- Operating pressure: 1.4–8.6 bar
- Operating temperature: 4–43°C
- Drain connection: 2" male BSPT 90° QC elbow
- Power supply: 100–240 VAC, 50/60 Hz input; 15 VDC output
- Height above tank: approximately 317.5 mm
- Shipping weight: approximately 4.98 kg
Programmable Filter Cycles
The WS2 CI controller can be configured with up to nine regeneration stages in the required sequence. Available filter functions include backwash, rinse and pause/service, allowing the valve to be adapted to a wide range of commercial filtration media and applications.
Please note: this version is supplied as a timed filter valve kit with no DLFC. The correct drain flow control should be selected separately according to the filter vessel diameter, media and required backwash flow.