The space-saving under-sink reverse osmosis unit is used for the desalination of softened water with a salinity of up to 1,000 mg/l. If required, operation without upstream softening is also possible, in which case the yield is reduced. The decisive factor is the water analysis. The RO 524 controller allows fully automatic operation without logging of operation data and with fixed, factory-set limit values.

Conductivity meter included.


Benefits

Available from stock
Space-saving under sink unit
Desalination of hard water also possible (reduced yield)
Cost-effective, factory-preset RO 524 controller
Permeate conductivity measurement

Applications
Desalination of softened water and hard water (consider water analysis)
Suitable for commercial applications that do not require operation data logging and parametrization

Controller: RO 524
Desalination rate min.: 95 %
Permeate recovery: 35 – 50 %
Permeate back pressure max.: 0.3 bar
pH value operation: 3.6 – 9.5
pH value cleaning: 2 – 12
Ambient temperature: 5 – 40 °C
Conditions of use: The unit may only be used for the desalination of softened feed water of drinking water quality or appropriately pre-treated well or surface water. The plant is designed for a salinity (TDS) of 1,000 mg/l and a temperature of 15 °C. Under these conditions, the projected permeate output is achieved even after three years of operation. The permeate yield depends on the raw water quality and the pre-treatment. The following parameters must be maintained in the feed water:
Free chlorine: not detectable
Iron (Fe): < 0.2 mg/l
Manganese (Mn): < 0.05 mg/l
Silica (SiO2): < 25 mg/l
Silt density index (SDI): < 3
Feed water temperature: 5 – 35 °C
Feed water pressure: 3 – 6 bar
Pressure fluctuation: ± 0.5 bar

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Frequently Asked Questions

What output and salt rejection are specified for this Herco RO system?
The model is rated at 130 litres per hour under its stated design conditions, with a minimum desalination rate of 95% and permeate recovery of 35–50%.
What feed-water conditions are required?
The design basis is softened drinking-quality or appropriately pre-treated water up to 1,000 mg/l TDS at 15°C. Feed pressure is 3–6 bar, temperature 5–35°C, and free chlorine must be undetectable. A water analysis is essential.
What controller and monitoring are included?
It includes the factory-preset RO 524 controller and permeate conductivity measurement. The controller provides automatic operation but does not log operating data.
What is the main function of the Herco Budget 130 lph Reverse Osmosis System?
The Herco Budget 130 lph Reverse Osmosis System is designed for desalinating softened water with a salinity up to 1,000 mg/l, providing clean and safe drinking water.
Can the Herco Budget 130 lph Reverse Osmosis System be used without upstream softening?
Yes, operation without upstream softening is possible, but it may result in reduced yield. The water analysis will determine the suitability for such use.
What features does the Herco Budget 130 lph Reverse Osmosis System include?
This system features a space-saving design, a fully automatic RO 524 controller with fixed preset limit values, and a permeate conductivity meter for precise measurement.
Is the Herco Budget 130 lph Reverse Osmosis System suitable for commercial use?
Yes, it is suitable for commercial applications that do not require detailed operation data logging and parameter adjustments, making it a cost-effective desalination solution.
What water quality parameters need to be maintained for optimal performance of the Herco Budget 130 lph Reverse Osmosis System?
To ensure optimal performance, the feed water should have no detectable free chlorine, iron less than 0.2 mg/l, manganese below 0.05 mg/l, silica under 25 mg/l, SDI less than 3, with a temperature of 5–35°C and pressure between 3–6 bar.