Welcome to GAPS Water Treatment learn more

Fast delivery starting from £9.00 Learn more

Order online, email or call with you order!

HI-7039L 5000 uS/cm Conductivity Solution, 500mL bottle

SKU: HI-7039L
Regular price £33.34
Shipping calculated at checkout.

Technical Resources

Questions & Answers loading...

HI-7039L 5000 µS/cm Conductivity Calibration Solution, 500 mL

The HI-7039L 5000 µS/cm Conductivity Calibration Solution is your go-to product for accurate and reliable conductivity meter calibration. Specially formulated for higher reading accuracies, it is ideal for applications requiring conductivity measurements between 2000 µS/cm and 10,000 µS/cm. Packaged in a conveniently sized 500 mL bottle, this calibration solution ensures precision and consistency whether you're working in agriculture, laboratories, or industrial setups.

Why Choose the HI-7039L Calibration Solution?

  • High Accuracy Calibration: Perfect for instruments used in mid to high-range conductivity applications, enabling precise calibration for consistent results.
  • Versatile Applications: Widely used in agricultural practices to monitor and prepare nutrient solutions for optimal crop production.
  • Trusted Hanna Quality: Developed with premium materials to deliver accurate conductivity testing every time.

Key Features and Specifications

Feature Details
Conductivity Value at 25°C 5000 µS/cm
Package Size 500 mL bottle
Seal Airtight, tamper-proof
Usage Range Ideal for 2000 µS/cm to 10,000 µS/cm measurement accuracy
Batch Information Includes batch number and expiry date
Compliance Prepared with NIST-traceable standards
Storage Instructions Store at room temperature, away from direct sunlight

What’s Included in the Package

  • 1 x 500 mL bottle of HI-7039L 5000 µS/cm Conductivity Calibration Solution

Benefits of the HI-7039L Calibration Solution

  • Enhanced Accuracy: Achieves reliable calibration for electrodes measuring medium to high conductivity ranges.
  • Easy to Use: Comes pre-mixed and ready, simplifying the calibration process while saving valuable time.
  • Complete Traceability: Clearly labeled with batch and expiry details for assured quality and confidence.
  • Tailored for Agriculture: Perfect for managing conductivity levels in nutrient solutions, promoting healthier crop yields.

How to Use the HI-7039L Calibration Solution

  1. Prepare the Calibration Solution: Pour the required amount into a clean, non-reactive container.
  2. Calibrate Your Instrument: Immerse the electrode in the solution and follow the manufacturer’s calibration instructions.
  3. Post-Use Care: Rinse the electrode with deionized water to maintain cleanliness and integrity.
  4. Store Correctly: After use, tightly reseal the bottle and keep it stored in a cool, shaded location to preserve accuracy.

Ideal Applications

  • Agriculture: Accurate calibration ensures nutrient solutions are optimized to support crop health and production.
  • Industry: Delivers reliable performance for quality control processes needing precise conductivity measurements.
  • Laboratories: Provides dependable calibration for research and analysis involving medium to high conductivity solutions.
  • Educational Use: Simplifies calibration for students and professionals in training labs.

Reliable Mid-Range Calibration for Every Application

The HI-7039L 5000 µS/cm Conductivity Calibration Solution ensures your instruments provide consistent, accurate results in every calibration. With calibration solutions developed to NIST standards and specifically designed for mid to high-range applications, this product is trusted by professionals across numerous industries. It's the ultimate tool for precision conductivity testing.

Order the HI-7039L Calibration Solution today and elevate the accuracy of your conductivity measurements!

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Frequently Asked Questions

What is the main use of the HI-7039L 5000 μS/cm Conductivity Calibration Solution?
The HI-7039L 5000 μS/cm Conductivity Calibration Solution is primarily used for calibrating conductivity meters in applications requiring measurements between 2000 μS/cm and 10,000 μS/cm, ensuring accurate and reliable conductivity testing.
How does the HI-7039L calibration solution improve measurement accuracy?
This calibration solution is formulated for high accuracy in mid to high-range conductivity applications, helping ensure your instruments provide precise and consistent readings during calibration.
What industries or applications is the HI-7039L solution suitable for?
It is ideal for agricultural nutrient management, industrial quality control, laboratory research, and educational purposes where medium to high conductivity measurements are required.
What are the storage instructions for the HI-7039L calibration solution?
Store the calibration solution at room temperature, away from direct sunlight, and keep the bottle tightly sealed to maintain its accuracy and effectiveness.
What components are included in the package of the HI-7039L calibration solution?
The package includes one 500 mL bottle of the HI-7039L 5000 μS/cm Conductivity Calibration Solution, designed for easy and precise calibration of conductivity meters.